ORDER NO. |
DESCRIPTION |
DETAIL |
REMARK |
SIMOVERT MASTERDRIVES COMPACT AND CHASSIS OPTIONS |
G11/13/14/15/16/17 |
COMMUNICATION BOARD PROFIBUS CBP |
|
PLUGGED INTO SLOT A-G |
G21/23/24/25/26/27 |
COMMUNICATION BOARD CAN-BUS CBC |
|
PLUGGED INTO SLOT A-G |
G41/43/44/45/46/47 |
COMMUNICATION BOARD SIMOLINK SLB |
|
PLUGGED INTO SLOT A-G |
G61/63/64/65/66/67 |
TERMINAL EXTENSION BOARD EB1 |
|
PLUGGED INTO SLOT A-G |
G71/73/74/75/76/77 |
TERMINAL EXTENSION BOARD EB2 |
|
PLUGGED INTO SLOT A-G |
G91/93/95/97 |
Communication board PROFIBUS CBP2, plugged into slot A/C/E/G |
|
|
K11 |
LOCAL BUS ADAPTER LBA |
|
BUILT INTO THE ELECTRONIC BOX |
K01, K02 |
ADAPTER BOARD ADB |
|
PLUGGED INTO POSITION 2, 3 |
L03 |
GROUND INTERFERENCE SUPPRESSION WHEN EMC FILTERS ARE USED, FOR SIZE J TO Q |
|
|
K80 |
SAFE OFF |
FOR CONVERTERS AND INVERTERS SIZE J TO Q |
|
M20 |
IP20 PANEL |
SIZE E |
ASSEMBLED WITH THE DRIVE |
M20 |
IP20 PANEL |
SIZE F |
ASSEMBLED WITH THE DRIVE |
M20 |
IP20 PANEL |
SIZE G |
ASSEMBLED WITH THE DRIVE |
L30 |
Inverter fuses installed size E to G |
|
|
L33 |
Compact inverters without fuses |
|
|
|
|
|
|
SIMOVERT MASTERDRIVES ELECTRONIC OPTIONS |
6SX70050AA00 |
Interface converter, SU1 RS232-RS485, incl.mounting accessories;supply, 1AC 115/230V |
|
|
6SX70100EJ00 |
Voltage sensing board VSB |
|
|
6SX70100FA00 |
Pulse generator board SBP, retrofit kit with short-form instruction |
|
|
6SX70100FF05 |
COMMUNICATION BOARD PROFIBUS CBP2 |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SX70100FG00 |
COMMUNICATION BOARD CAN-BUS CBC |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SX70100FJ00 |
COMMUNICATION BOARD SIMOLINK SLB |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SX70100FJ50 |
System package for SLB with connectors and 100mplastic fiber optic cable |
|
|
6SX70100KB00 |
TERMINAL EXTENSION BOARD EB1 |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SX70100KC00 |
TERMINAL EXTENSION BOARD EB2 |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SE70900XX844HA0 |
LOCAL BUS ADAPTER LBA |
RETROFIT KIT WITH SHORT-FORM INSTRUCTION |
|
6SX70100KA00 |
ADAPTER BOARD ADB |
CONNECTOR AND SHORT-FORM |
|
6SE70900XX870BB0 |
TECHNOLOGY BOARD T100 |
INCLUDING HW MANUAL, WITHOUT SW |
|
6SE70980XX840BB0 |
SOFTWARE MODULE MS100 |
UNIVERSAL DRIVE WITHOUT MANUAL |
|
6SE70800CX870BB0 |
OPERATION MANUAL FOR HW OF T100 |
FOR ADDITIONAL DEMAND ONLY |
|
6SE70876CX840BB0 |
MANUAL FOR SOFTWAREMODULE MS100 |
UNIVERSAL DRIVE (ENGLISH) |
|
6SE70900XX874AH0 |
TECHNOLOGY BOARD T300 |
INCLUDING HARDWARE MANUAL (GER/ENGL) |
|
6SE70876CX840AH0 |
OPERATION MANUAL FOR HW OF T300 |
FOR ADDITIONAL DEMAND ONLY (GER/ENG) |
|
6SE70982XX840AH0 |
STANDARD-SOFTWARE MS320 FOR T300 |
CENTER WINDER, WITHOUT MANUAL |
|
6SE70984XX840AH0 |
STANDARD-SOFTWARE MS340 FOR T300 |
ANGLE-CONTROL, WITHOUT MANUAL |
|
6SE70986XX840AH0 |
STANDARD-SOFTWARE MS360 FOR T300 |
SECTIONAL DRIVE, WITHOUT MANUAL |
|
6SE70988XX840AH0 |
STANDARD-SOFTWARE MS380 FOR T300 |
POSITIONING-CONTROL, WITHOUT MANUAL |
|
6SE70876CX842AH0 |
MANUAL FOR MS320 |
CENTER WINDER (ENGLISH) |
|
6SE70876CX844AH0 |
MANUAL FOR MS340 |
ANGLE-CONTROL (ENGLISH) |
|
6SE70876CX846AH0 |
MANUAL FOR MS360 |
SECTIONAL DRIVE (ENGLISH) |
|
6SE70876CX848AH0 |
MANUAL FOR MS380 |
POSITIONING-CONTROL (ENGLISH) |
|
6SE70900XX840AB0 |
|
|
|
6SE70900XX840BC0 |
SERIAL INTERFACE BOARD SCB1 |
|
|
6SE70900XX840BD1 |
SERIAL INTERFACE BOARD SCB2 |
|
|
6SE70900XX840BA0 |
TACHOMETER AND SYNCHRONISING BOARD TSY |
|
|
6SE70900XX842FK0 |
OP1S, operator control panel |
|
|
6SE70900XX843EA0 |
SERIAL INTERFACE BOARD SCI1 |
FOR ANALOGUE AND BINARY SIGNALS |
|
6SE70900XX843EF0 |
SERIAL INTERFACE BOARD SCI2 |
FOR BINARY SIGNALS |
|
6SE70900XX843DF0 |
INTERFACE BOARD ATI |
FOR ANALOG TACHOMETER |
|
6SE70900XX843DB0 |
INTERFACE BOARD DTI |
FOR DIGITAL TACHOMETER |
|
6SE70900XX843DB1 |
Interface board DTI, for digital tachometer with short-form instruction |
|
|
|
|
|
|
SIMOVERT MASTERDRIVES OTHER OPTIONS |
6SE70900XX873CB0 |
BRACKETS FOR 30 AND 40MM HIGH BUSWAYS WITH MOUNTING INSTRUCTIONS |
|
|
6SE70900XX873CD0 |
BRACKETS FOR 50 AND 60MM HIGH BUSWAYS WITH MOUNTING INSTRUCTIONS |
|
|
6SE70900XA873CA1 |
CONNECTING ADAPTER FOR CABLE LOOMS, SIZE A |
|
|
6SE70900XB873CA1 |
CONNECTING ADAPTER FOR CABLE LOOMS, SIZE B |
|
|
6SE70900XC873CA1 |
CONNECTING ADAPTER FOR CABLE LOOMS, SIZE C |
|
|
6SE70900XD873CA1 |
CONNECTING ADAPTER FOR CABLE LOOMS, SIZE D |
|
|
6SE70900XE873AC0 |
IP20 PANEL |
SIZE E |
RETROFIT KIT |
6SE70900XF873AC0 |
IP20 PANEL |
SIZE F |
RETROFIT KIT |
6SE70900XG873AC0 |
IP20 PANEL |
SIZE G |
RETROFIT KIT |
|
|
|
|
OPERATOR CONTROL PANELS AND ADAPTER BOARDS |
K08 |
OP1S |
WITH OP1 OPERATOR CONTROL PANEL ON CABINET DOOR |
|
K11 |
LBA |
LOCAL BUS ADAPTER FOR THE ELECTRONIC BOX |
|
K01, K02 |
ADB |
ADAPTER BOARD PLUGGED INTO POSITION 2, 3 |
|
|
|
|
|
TECHNOLOGY BOARDS |
K12 |
T300 |
TECHNOLOGY BOARD |
|
K16 |
T100 |
TECHNOLOGY BOARD |
|
K13 |
SE300 |
TERMILA BLOCK FOR T300 |
|
K30 |
TSY |
DIGITAL TACHOMETER AND SYNCHRONIZING BOARD |
|
|
|
|
|
SOFTWARE MODULES FOR TECHNOLOGY BOARDS |
B10 |
MS100 |
UNIVERSAL DRIVE SW FOR T100 |
|
B32 |
MS320 |
CENTER WINDER SW FOR T300 |
|
B34 |
MS340 |
ANGLE-CONTROL SW FOR T300 |
|
B36 |
MS360 |
SECTIONAL DRIVE SW FOR T300 |
|
B38 |
MS380 |
POSITIONING-CONTROL SW FOR T300 |
|
|
|
|
|
EXPANSION BOARDS |
G61/63/64/65/66/67 |
EB1 |
PLUGGED INTO SLOT A/C/D/E/F/G |
|
G71/73/74/75/76/77 |
EB2 |
PLUGGED INTO SLOT A/C/D/E/F/G |
|
|
|
|
|
INTERFACE BOARDS AND AUXILIARY POWER SUPPLY UNITS |
K20 |
SCB1 |
SERIAL INTERFACE BOARD SCB1 |
|
K21 |
SCB2 |
SERIAL INTERFACE BOARD SCB2 |
|
K41 |
SCI1 |
SERIAL INTERFACE BOARD FOR ANALOGUE AND BINARY SIGNALS |
|
K42 |
2*SCI1 |
SERIAL INTERFACE BOARD FOR ANALOGUE AND BINARY SIGNALS |
|
K50 |
DTI |
INTERFACE BOARD DTI FOR DIGITAL TACHOMETER |
|
K51 |
DTI FOR T300 |
INTERFACE BOARD DTI FOR DIGITAL TACHOMETER |
|
K60 |
ATI |
INTERFACE BOARD FOR ANALOG TACHOMETER |
|
K73 |
POWER SUPPLY |
230VAC-24VDC |
|
K74 |
POWER SUPPLY |
380VAC-230VAC |
|
|
|
|
|
COMMUNICATION BOARDS |
G11/13/14/15/16/17 |
CBP |
PLUGGED INTO SLOT A/C/D/E/F/G |
|
G21/23/24/25/26/27 |
CBC |
PLUGGED INTO SLOT A/C/D/E/F/G |
|
G41/43/44/45/46/47 |
SLB |
PLUGGED INTO SLOT A/C/D/E/F/G |
|
|
|
|
|
ISOLATION AMPLIFIERS FOR ANOLOG INPUTS AND OUTPUTS |
E06 |
ANALOG OUTPUT 1 |
-10V TO +10V / -10V TO +10V |
|
E07 |
ANALOG OUTPUT 2 |
-10V TO +10V / -10V TO +10V |
|
E16 |
ANALOG OUTPUT 1 |
-10V TO +10V / -20mA TO +20mA |
|
E17 |
ANALOG OUTPUT 2 |
-10V TO +10V / -20mA TO +20mA |
|
E26 |
ANALOG OUTPUT 1 |
0V TO +10V / 4mA TO 20mA |
|
E27 |
ANALOG OUTPUT 2 |
0V TO +10V / 4mA TO 20mA |
|
E46 |
ANALOG INPUT 1 |
0(4)mA TO 20mA / 0(4)mA TO 20mA |
|
E47 |
ANALOG INPUT 2 |
0(4)mA TO 20mA / 0(4)mA TO 20mA |
|
E56 |
ANALOG INPUT 1 |
-10V TO +10V / -10V TO +10V |
|
E57 |
ANALOG INPUT 2 |
-10V TO +10V / -10V TO +10V |
|
E66 |
ANALOG INPUT 1 |
-20mA TO +20mA / -10V TO +10V |
|
E67 |
ANALOG INPUT 2 |
-20mA TO +20mA / -10V TO +10V |
|
|
|
|
|
RADIO INTERFERENCE SUPPRESSION FILTER |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
45KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
55KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
75KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
90KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
110KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
132KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
160KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
200KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
250KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
315KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
400KW |
L00 |
FOR CONVERTER CABINET, 6 PULSE |
|
500KW |
|
|
|
|
OUTPUT REACTOR IRON CORE |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
45KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
55KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
75KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
90KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
110KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
132KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
160KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
200KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
250KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
315KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
400KW |
L08 |
FOR CONVERTER CABINET, 6 PULSE |
|
500KW |
|
|
|
|
OUTPUT REACTOR FERRITE CORE |
L09 |
|
|
|
|
|
|
|
VOLTAGE LIMITING FILTER (DV/DT) |
L10 |
|
|
|
|
|
|
|
SINUSOIDAL FILTER |
L15 |
|
|
|
|
|
|
|
ADDITIONAL CONTROL FUNCTIONS |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
45KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
55KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
75KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
90KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
110KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
132KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
160KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
200KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
250KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
315KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
400KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
500KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
630KW |
L13 |
FOR CONVERTER CABINET, 6 PULSE |
|
710KW |
L41 |
TERMINAL STRIP FOR BINARY INPUTS AND OUTPUTS |
|
|
L42 |
TERMINAL STRIP FOR ANALOG INPUTS AND OUTPUTS |
|
|
|
|
|
|
BRAKING UNITS (INTEGRATED IN CABINET) |
L64 |
10kW |
|
|
L67 |
20kW |
|
|
L71 |
50kW |
|
|
L74 |
100kW |
|
|
L77 |
170kW |
|
|
|
|
|
|
BRAKING RESISTORS (SUPPLIED SEPARATELY) |
C64 |
10kW |
|
|
C67 |
20kW |
|
|
C71 |
50kW |
|
|
C74 |
100kW |
|
|
C77 |
170kW |
|
|
|
|
|
|
MECHANICAL COMPONENTS AND OPTIONS |
M05 |
CABINET SIZE B |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE C |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE D |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE E |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE G |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE H |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M05 |
CABINET SIZE J |
CABINET, SEALED WITH BASEPLATE AT THE BOTTOM |
|
M23 |
CABINET SIZE B |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE C |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE D |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE E |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE G |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE H |
DEGREE OF PROTECTION IP23 |
|
M23 |
CABINET SIZE J |
DEGREE OF PROTECTION IP23 |
|
M43 |
CABINET SIZE B |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE C |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE D |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE E |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE G |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE H |
DEGREE OF PROTECTION IP43 |
|
M43 |
CABINET SIZE J |
DEGREE OF PROTECTION IP43 |
|
M70 |
CABINET SIZE B |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE C |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE D |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE E |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE G |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE H |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M70 |
CABINET SIZE J |
EMC SHIELD FOR CONVERTER OUTPUT |
|
M75 |
CABINET SIZE B |
PE BUS |
|
M75 |
CABINET SIZE C |
PE BUS |
|
M75 |
CABINET SIZE D |
PE BUS |
|
M75 |
CABINET SIZE E |
PE BUS |
|
M75 |
CABINET SIZE G |
PE BUS |
|
M75 |
CABINET SIZE H |
PE BUS |
|
M75 |
CABINET SIZE J |
PE BUS |
|
|
|
|
|
SIMOVERT MASTERDRIVES DOCUMENTATION |
6SE7087-6NX60 |
GERMAN/ENGLISH |
COLLECTED OPERATION INSTRUCTIONS |
|
6SE7085-0NX60 |
CHINESE |
COLLECTED OPERATION INSTRUCTIONS |
|
6SE7080-0QX60 |
GERMAN |
COMPENDIUM |
|
6SE7087-6QX60 |
ENGLISH |
COMPENDIUM |
|
6SE7085-0QX60 |
CHINESE |
COMPENDIUM |
|
|
|
|
|